rss
J Clin Pathol 2009;62:147-151 doi:10.1136/jcp.2008.059477
  • Original article

Development and validation of a ζ-globin-specific ELISA for carrier screening of the (−−SEA) α thalassaemia deletion

  1. L Tang1,
  2. P Zhu1,
  3. W J Zhou2,
  4. J Zheng1,
  5. Y Q Zhou3,
  6. N Fu1,
  7. X M Xu2
  1. 1
    Department of Immunology, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China
  2. 2
    Department of Medical Genetics, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China
  3. 3
    Zhuhai Institute of Medical Genetics, Zhuhai Municipal Maternal and Child Healthcare Hospital, Zhuhai, Guangdong, China
  1. Xu Xiangmin, Department of Medical Genetics, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China; gzxuxm{at}hotmail.com
  • Accepted 22 September 2008

Abstract

Aims: The Southeast Asian (SEA) deletion (−−SEA) represents the most common determinant causing α thalassaemia in Southeast Asian countries. The embryonic ζ-globin chain has been defined as a marker for the detection of this deletion in adults. The aim of this study was to develop an appropriate low-cost ELISA for ζ-globin chain detection as a routine screening test for (−−SEA) α thalassaemia deletion.

Methods: A sandwich ELISA system for ζ-globin chains was established with a pair of ζ-globin-specific monoclonal antibodies prepared in-house, and locally made products. Against a gap-PCR method that was taken as the standard, this assay was validated in a cohort study testing a total of 526 individuals comprising patients scheduled for haemoglobinopathy diagnostic analysis and normal individuals. Routine screening of the (−−SEA) deletion in 300 random student volunteers was conducted using the assay.

Results: While the cut-off point was set at a percentage positive value of 30, the sensitivity and specificity of this ELISA method were 100% and 99.24%, respectively. The mean intra-assay and inter-assay coefficients of variation among the different concentrations in the optimised ELISA conditions were 2.1–11.4% and 4.3–13.2%, respectively. Seventeen of the 300 volunteers sampled were determined by the ELISA to have the (−−SEA) deletion; these results were in 100% agreement with the gap-PCR results.

Conclusions: This study validates the ELISA method described here as a simple, rapid and cost-effective assay that is potentially adaptable for application in large-scale population screening for this prevalent disorder in SEA areas such as southern China.

Footnotes

  • Competing interests: None declared.

Latest from JCP Education

Latest from JCP Education

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of JCP.
View free sample issue >>

Free archive
The full back archive is now available for JCP. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

  • Latest Pathology jobs

    Latest Pathology jobs