Analytical and diagnostic accuracy of “second generation” assays for thyrotrophin receptor antibodies with radioactive and chemiluminescent tracers

  1. D Villalta1,
  2. E Orunesu2,
  3. R Tozzoli3,
  4. P Montagna2,
  5. G Pesce2,
  6. N Bizzaro4,
  7. M Bagnasco2
  1. 1Clinical Immunology and Virology Unit, City Hospital Pordenone, Via Montereale 24, 33170 Pordenone, Italy
  2. 2Autoimmunity Laboratory, Medical and Radiometabolic Therapy Unit, DI.M.I. University of Genoa, Viale Benedetto XV 6, 16132 Genoa, Italy
  3. 3Clinical Pathology Unit, City Hospital Latisana, Via Sabbionera 45, 33053 Latisana, Italy
  4. 4Clinical Pathology Unit, City Hospital San Donà di Piave, Via N. Sauro 25, 30027 San Donà di Piave, Italy
  1. Correspondence to:
 Dr M Bagnasco
 Autoimmunity Laboratory, Medical and Radiometabolic Therapy Unit, DI.M.I. University of Genoa, Viale Benedetto XV 6, 16132 Genoa, Italy; allerlabunige.it
  • Accepted 26 November 2003

Abstract

Aims: To investigate the analytical and diagnostic accuracy of thyrotrophin (TSH) receptor antibody assays using recombinant human TSH receptors.

Methods: Sera from 68 patients with Graves’ disease, 23 patients with autoimmune thyroiditis, and 119 healthy controls were evaluated in four different laboratories using both radioactive and chemiluminescent tracers. Functional sensitivity, interlaboratory precision, optimal cutoff values for Graves’ disease, and the correlation between the two methods were evaluated.

Results: Functional sensitivity was 0.98 IU/litre for both assays. Interlaboratory precision, expressed as per cent coefficient of variation over a wide range of antibody concentrations, varied from 5.7% to 15.1% for the radioligand, and from 6.6% to 19.9% for the chemiluminescence assay. The two methods (radioactive and chemiluminescent) were closely correlated. All the sera from untreated or relapsing patients with Graves’ disease gave TSH receptor antibody values above 2.1 IU/litre, whereas in none of the healthy controls did values exceed 2.5 IU/litre. Receiver operating curve analysis allowed an optimal cutoff point to be defined at 1.99 IU/litre, according to a sensitivity of 100% and specificity of 99.1%.

Conclusions: These data show the high analytical and diagnostic accuracy of the human TSH receptor assays, both with radioactive and chemiluminescent tracers, when both functional sensitivity and interlaboratory reproducibility are considered. These two methods could be proposed as first line diagnostic markers for Graves’ disease.

Footnotes

    This Article

    Services

    1. Request permissions

    Responses

    1. Submit a response
    2. No responses published

    Social bookmarking

    Latest from JCP Education

    Latest from JCP Education

    Register for free content


    Free sample
    This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of JCP.
    View free sample issue >>

    Free archive
    The full back archive is now available for JCP. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
    Register to access the free archive >>

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

  • Latest Pathology jobs

    Latest Pathology jobs