rss
J Clin Pathol 2002;55:824-828 doi:10.1136/jcp.55.11.824
  • Original article

DNA fingerprinting analysis of coagulase negative staphylococci implicated in catheter related bloodstream infections

  1. B M Dobbins,
  2. P Kite,
  3. A Kindon,
  4. M J McMahon,
  5. M H Wilcox
  1. Departments of Microbiology and Surgery, Leeds General Infirmary and University of Leeds, Leeds LS1 3EX, UK
  1. Correspondence to:
 Dr M H Wilcox, Department of Microbiology, University of Leeds and The General Infirmary, Leeds LS2 9JT, UK;
 markwi{at}pathology.leeds.ac.uk
  • Accepted 25 June 2002

Abstract

Aims: The epidemiological assessment of cases of coagulase negative staphylococcal catheter related bloodstream infection.

Methods: Two hundred and thirty patients with suspected catheter related bloodstream infection were evaluated over a two year period. Central venous catheters were cultured both endoluminally and extraluminally. Peripheral blood, catheter hubs, skin entry, and skin control sites were also cultured. Pulsed field gel electrophoresis (PFGE) was used to DNA fingerprint coagulase negative staphylococci isolated from patients with presumptive catheter related bloodstream infection.

Results: Sixty cases of catheter related bloodstream infection were identified, 21 of which were attributed to coagulase negative staphylococci. Two hundred and ninety four separate isolates of coagulase negative staphylococci from the 21 cases of catheter related bloodstream infection were subjected to PFGE (mean of 14 for each case). Catheter related bloodstream infection was only confirmed by PFGE analysis in 16 of the 21 cases because in the remaining five cases peripheral blood and central venous catheter coagulase negative staphylococci isolates were different. Skin entry, control skin, and central venous catheter hub isolates matched peripheral blood isolates in six, four, and seven cases, respectively. Coagulase negative staphylococci isolates could not be cultured from the patients’ own skin in seven cases of catheter related bloodstream infection. Central venous catheter lumens were colonised in all cases of catheter related bloodstream infection compared with 44–81% of cases that had positive external surface catheter tip cultures, depending on the threshold used to define significant growth.

Conclusions: Catheter related bloodstream infection as a result of coagulase negative staphylococci may be over stated in about a quarter of cases, unless a discriminatory technique is used to fingerprint isolates. No single, simplistic route of bacterial contamination of central venous catheters was identified, but endoluminal catheter colonisation is invariably present in cases of catheter related bloodstream infection.

Footnotes

    Latest from JCP Education

    Latest from JCP Education

    Register for free content


    Free sample
    This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of JCP.
    View free sample issue >>

    Free archive
    The full back archive is now available for JCP. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
    Register to access the free archive >>

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

  • Latest Pathology jobs

    Latest Pathology jobs