Ultrasound enhanced detection of individual meningococcal serogroups by latex immunoassay

  1. M A Sobanski1,
  2. R Vince1,
  3. G A Biagini1,
  4. C Cousins1,
  5. M Guiver2,
  6. S J Gray2,
  7. E B Kaczmarski2,
  8. W T Coakley1
  1. 1School of Biosciences, Cardiff University, Cardiff CF10 3TL, UK
  2. 2Public Health Laboratory Service Meningococcal Reference Unit, Manchester Public Health Laboratory, M20 2LR, UK
  1. Correspondence to:
 Professor W T Coakley, School of Biosciences, Cardiff University, Cardiff CF10 3TL UK;
 Coakley{at}cardiff.ac.uk
  • Accepted 31 July 2001

Abstract

Aims: To examine A, C, Y, and W135 Neisseria meningitidis serogroup characterisation by ultrasonic standing wave enhanced latex agglutination tests (USELATs) of clinical samples. In addition, to determine USELAT enhancement of detection sensitivity for the individual antigens compared with conventional card latex agglutination tests (LATs).

Methods: Wellcogen (Abbott Murex), Slidex meningite kit 5 (bioMerieux), and Pastorex (Sanofi) kits and beads coated in house with antibodies to Y and to W135 alone were tested. Positive control antigens consisted of A and C polysaccharide preparations and the Pastorex Y/W135 kit sample. The limiting concentrations of antigen detection were determined by USELAT and by LAT. Thirty five clinical samples (plasma), previously characterised by the polymerase chain reaction (PCR) and culture, were tested by USELAT and, when sample volume allowed, by LAT.

Results: USELAT enhancement of control antigen detection ranged from 16 to 128 fold for the different latex systems. Enhancements for the different control antigens were comparable between kits. USELAT tests of clinical (A/C/Y/W135) samples (n = 15) with the Wellcogen (A/C/Y/W135) and Slidex meningite (A/C/Y/W135) kits showed comparable specificities. A set (n = 22) of Y and W135 samples gave 18, 19, and 17 positive results for Wellcogen (A/C/Y/W135), Pastorex (A/C/Y/W135), and in house beads (Y/W135), respectively. Positive USELAT PCR and culture results were concordant. A typical sensitivity for the commercial kits was 80% (Wellcogen).

Conclusions: USELAT identified serogroups for 80% of samples, whereas LATs identified only 40%. The USELAT detection of the A, C, Y, and W135 antigen serogroups showed comparable enhancement for the kits tested. The commercial availability of latex beads coated with antibody to the Y and W135 serogroups would expedite their identification.

Footnotes

    This Article

    Services

    1. Request permissions

    Responses

    1. Submit a response
    2. No responses published

    Social bookmarking

    Latest from JCP Education

    Latest from JCP Education

    Register for free content


    Free sample
    This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of JCP.
    View free sample issue >>

    Free archive
    The full back archive is now available for JCP. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
    Register to access the free archive >>

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

  • Latest Pathology jobs

    Latest Pathology jobs