rss
J Clin Pathol 1973;26:140-145 doi:10.1136/jcp.26.2.140
  • Articles

Controlling infection in a district general hospital

  1. Paul Noone1,
  2. M. S. Shafi
  1. Bacteriology Department, Central Middlesex Hospital, London

      Abstract

      The way in which hospital-acquired infection has been brought under control over a three-year period in a district general hospital is described.

      The main success has been achieved in reducing sepsis caused by Staph. aureus, especially methicillin-resistant strains, and Pseudomonas aeruginosa.

      These reductions were achieved in spite of inadequate ward isolation and operating theatre facilities, and before there was any marked change in patterns of prescribing antibiotics.

      Our experiences indicate the significant improvements that can be made in controlling nosocomial sepsis even without structural or other major alterations in a hospital, providing that the problem is fully appreciated and the infection control team are concerned enough to act vigorously in influencing their clinical colleagues.

      Footnotes

      • 1 Present address: Bacteriology Department, Royal Free Hospital, London WC1X 8LF.

      Latest from JCP Education

      Latest from JCP Education

      Register for free content


      Free sample
      This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of JCP.
      View free sample issue >>

      Free archive
      The full back archive is now available for JCP. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
      Register to access the free archive >>

      Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

    • Latest Pathology jobs

      Latest Pathology jobs