JCP

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

Published Online First: 10 August 2007. doi:10.1136/jcp.2007.048991
Journal of Clinical Pathology 2008;61:278-282
Copyright © 2008 by the BMJ Publishing Group Ltd & Association of Clinical Pathologists.

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jcp.2007.048991v1
61/3/278    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Konsti, J
Right arrow Articles by Isola, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Konsti, J
Right arrow Articles by Isola, J

ORIGINAL ARTICLES

A public-domain image processing tool for automated quantification of fluorescence in situ hybridisation signals

J Konsti1, J Lundin1, M Jumppanen2,3, M Lundin1, A Viitanen2, J Isola2

1 Biomedical Informatics Research Group, Department of Oncology, University of Helsinki, Helsinki, Finland
2 Institute of Medical Technology, University of Tampere, Tampere, Finland
3 Department of Pathology, Seinäjoki Central Hospital, Seinäjoki, Finland

Correspondence to:
Juho Konsti, MB, Biomedical Informatics Research Group, Mailing address: HUCH Clinical Research Institute, Haartmaninkatu 4, PO Box 105, FIN-00029 Helsinki, Finland; juho.konsti{at}helsinki.fi

Aims: To develop and evaluate an automated method for quantification of HER2 fluorescence in situ hybridisation (FISH) signals.

Methods: Using a popular, open source image manipulation tool, ImageJ, a macro for FISH signal assessment was created. A comparison against traditional manual counting was performed in breast cancer specimens from 42 patients. The tumour specimens were hybridised with probes for HER2 and chromosome 17 centromere (CEP17) and selected areas were digitised for image processing. Hybridisation signals were calculated both manually and automatically with the ImageJ custom macro.

Results: The correlation coefficient between the automatic and manual HER2/CEP17 ratios was 0.98. The corresponding percentage agreement was 90% and the kappa value was 0.82.

Conclusions: This study shows that it is possible to automate the determination of HER2 amplification by the use of open-source software, with results comparable to manual counting. The automated counting decreases the time needed for sample analysis and provides possibilities to enhance inter- and intralaboratory reproducibility of results. The FISH quantification tool (FishJ) is available for download as an ImageJ macro or alternatively it can be utilised through a web interface with an option of uploading FISH images for hybridisation signal counting. Combined with digitisation of FISH samples, the FishJ macro enables gene copy number to be assessed and re-evaluated on any area of a digitised specimen.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Journal of Clinical Pathology Molecular Pathology
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2008 by the BMJ Publishing Group Ltd & Association of Clinical Pathologists.