JCP

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplementary Material
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Choesmel, V
Right arrow Articles by Blin, N
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Choesmel, V
Right arrow Articles by Blin, N
Related Collections
Right arrow Molecular Medicine
Right arrow Cancer: breast
Journal of Clinical Pathology 2004;57:1278-1287
© 2004 BMJ Publishing Group Ltd & Association of Clinical Pathologists


ORIGINAL ARTICLE

Design of a real time quantitative PCR assay to assess global mRNA amplification of small size specimens for microarray hybridisation

V Choesmel, F Foucault, J P Thiery, N Blin

UMR144 CNRS, Research Division, Institut Curie, 75248 Paris cedex 05, France

Correspondence to:
Dr N Blin
UMR144 CNRS, Research Division, Institut Curie, 75248 Paris cedex 05, France; Nathalie.Blin{at}curie.fr Background: Low RNA yields from clinical samples are a limiting step for microarray technology.

Aims: To design an accurate real time quantitative polymerase chain reaction (PCR) assay to assess the crucial step of global mRNA amplification performed before microarray hybridisation, using less than 1 µg total RNA.

Methods: Three RNA extraction procedures were compared for small size samples. Total RNA was amplified from universal RNA or the BC-H1 breast cancer micrometastatic cell line using three different protocols. Real time quantitative PCR technology was used for accurate measurement of urokinase plasminogen activator receptor and cytokeratin 8 RNA amplification rates and ratios, using primer sets binding at various distances from the 3' end of transcripts. A 50 mer oligomeric array targeting 87 genes potentially involved in breast cancer metastatic progression was built and hybridised with amplified RNA.

Results: Eighteen nanograms of total RNA could be purified from 1000 BC-H1 micrometastatic cells. Amplification rates of 25 000 to 100 000 were achieved with as little as 10 ng of starting material. However, results were highly variable, depending on the amount of starting material, gene characteristics, sample quality, and protocols used. Oligomeric array hybridisation with 20 µg reference RNA resulted in specific and reproducible signals for 83% of the genes, whereas mRNA amplification from less than 400 ng of starting material resulted in selective detection of signals from highly expressed genes.

Conclusions: Improvements in the design of global mRNA amplification procedures and oligomeric arrays are needed to extract informative gene expression data from clinical samples containing limited cell numbers.


Abbreviations: aRNA, antisense RNA; BM, bone marrow; Ct, cycle threshold; GAPDH, glyceraldehyde 3-phosphate dehydrogenase; IVT, in vitro transcription; Ker8, cytokeratin 8; PCR, polymerase chain reaction; RT, reverse transcription; rtqPCR, real time quantitative PCR; uPAR, urokinase plasminogen activator receptor; uRNA, universal RNA

Keywords: amplified RNA; in vitro transcription; real time quantitative PCR; oligomeric array; expression profiling







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Journal of Clinical Pathology Molecular Pathology
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2004 by the BMJ Publishing Group Ltd & Association of Clinical Pathologists.