JCP

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Poller, L
Right arrow Articles by Jespersen, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Poller, L
Right arrow Articles by Jespersen, J
Right arrowPubmed/NCBI databases
*Compound via MeSH
*Substance via MeSH
Hazardous Substances DB
*COUMARIN
Journal of Clinical Pathology 2003;56:114-119
© 2003 BMJ Publishing Group & Association of Clinical Pathologists


ORIGINAL ARTICLE

European Concerted Action on Anticoagulation (ECAA). An assessment of lyophilised plasmas for ISI calibration of CoaguChek and TAS whole blood prothrombin time monitors

L Poller1,*, M Keown1, N Chauhan1, A M H P van den Besselaar2,*, A Tripodi3,*, C Shiach4,*, J Jespersen5,*

1 ECAA Central Facility, School of Biological Sciences, The University of Manchester, Manchester M13 9PT, UK
2 Haemostasis and Thrombosis Research Centre, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
3 A Bianchi Bonomi, Haemophilia and Thrombosis Centre, IRCCS Maggiore Hospital, University of Milan, 20122 Milan, Italy
4 Department of Haematology, Manchester Royal Infirmary, Manchester M13 9WL, UK
5 Department for Thrombosis Research, University of Southern Denmark and Department of Clinical Biochemistry, Ribe County Hospital, Esbjerg DK-6700, Denmark

Correspondence to:
Professor L Poller, ECAA Central Facility, School of Biological Sciences, The University of Manchester, Manchester M13 9PT, UK;
ecaa{at}man.ac.uk

Aims: The recommended method for the international sensitivity index (ISI) calibration of whole blood point of care testing (POCT) prothrombin time (PT) systems was originally described by Tripodi et al in 1993 but is too complex and demanding. The present European Concerted Action on Anticoagulation (ECAA) study aimed to assess the reliability of simpler ISI calibration using lyophilised plasma samples.

Methods: ISI calibrations using three different types of ECAA lyophilised plasma samples (artificially depleted, individual, and pooled coumarin) were compared with whole blood calibrations on CoaguChek Mini and TAS PT-NC POCT monitors at 10 centres.

Results: With CoaguChek Mini systems, lyophilised coumarin plasma samples (both single donation and pooled) gave ISI and international normalised ratio (INR) values comparable to whole blood. With artificially depleted plasma, ISI and INR values were too high. With TAS PT-NC systems, all three types of lyophilised plasma samples gave inaccurate ISI and unreliable INR results, similar to previous ECAA findings with fresh plasma calibrations.

Conclusions: With CoaguChek Mini systems, ISI calibration can be simplified by the use of ECAA lyophilised plasma samples from coumarin treated patients. Further study is needed to devise a simpler calibration method for the TAS PT-NC system.


Keywords: prothrombin time; international sensitivity index; certified lyophilised plasmas; point of care test monitors

Abbreviations: ECAA, European Concerted Action on Anticoagulation; CV, coefficient of variation; INR, international normalised ratio; IRP, international reference preparation; ISI, international sensitivity index; MNPT, mean normal prothrombin time; POCT, point of care testing; PT, prothrombin time; RBT/90, rabbit plain international reference preparation; rTF/95, human recombinant international reference preparation; WHO, World Health Organisation




This article has been cited by other articles:


Home page
ChestHome page
J. Ansell, J. Hirsh, E. Hylek, A. Jacobson, M. Crowther, and G. Palareti
Pharmacology and Management of the Vitamin K Antagonists: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines (8th Edition)
Chest, June 1, 2008; 133(6_suppl): 160S - 198S.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
L. Poller, M. Keown, S. A. Ibrahim, F. J.M. van der Meer, A. M.H.P. van den Besselaar, A. Tripodi, J. Jespersen, European Action on Anticoagulation, P. Meijer, C. Kluft, et al.
Quality Assessment of CoaguChek Point-of-Care Prothrombin Time Monitors: Comparison of the European Community-Approved Procedure and Conventional External Quality Assessment.
Clin. Chem., October 1, 2006; 52(10): 1843 - 1847.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. Ansell, J. Hirsh, L. Poller, H. Bussey, A. Jacobson, and E. Hylek
The Pharmacology and Management of the Vitamin K Antagonists: The Seventh ACCP Conference on Antithrombotic and Thrombolytic Therapy
Chest, September 1, 2004; 126(3_suppl): 204S - 233S.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
L. Poller, M. Keown, N. Chauhan, A. M.H.P. van den Besselaar, A. Tripodi, C. Shiach, and J. Jespersen
European Concerted Action on Anticoagulation. Quality Assessment of the CoaguChek Mini and TAS PT-NC Point-of-Care Whole-Blood Prothrombin Time Monitors
Clin. Chem., March 1, 2004; 50(3): 537 - 544.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Journal of Clinical Pathology Molecular Pathology
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2003 by the BMJ Publishing Group Ltd & Association of Clinical Pathologists.