© 2002 Journal of Clinical Pathology
ORIGINAL ARTICLE
Immunofluorescent patterns produced by antineutrophil cytoplasmic antibodies (ANCA) vary depending on neutrophil substrate and conjugate
1 The University Department of Medicine, Austin and Repatriation Medical Centre, Heidelberg, VIC 3084, Australia
2 Members of the Australian ANCA study group
Correspondence to:
Correspondence to:
Professor J Savige, University Department of Medicine, Austin and Repatriation Medical Centre, Heidelberg VIC 3084, Australia;
jsavige{at}austin.unimelb.edu.au
Background: The "International consensus statement on testing and reporting antineutrophil cytoplasmic antibodies (ANCA)" advocates screening by indirect immunofluorescence (IIF), but external quality assessment programmes often demonstrate different IIF patterns for a single serum.
Aim: To determine whether the variation in IIF patterns can be attributed solely to errors in interpretation.
Methods: This study compared the IIF patterns produced by four sera (two with cytoplasmic or C-ANCA; one with perinuclear or P-ANCA with myeloperoxidase (MPO) specificity; and one P-ANCA without MPO specificity) that were tested in 11 different laboratories. The sera were examined according to individual laboratory protocols at dilutions of 1/10 to 1/40 using P1 (n = 4), P2 (n = 2), P3 (n = 2), or in house (n=3) neutrophil preparations and conjugates from manufacturers C1 (n = 3), C2 (n = 1), C3 (n = 2), C4 (n = 1), C5 (n = 2), and C6 (n = 2). The IIF patterns were noted in each laboratory, the testing repeated, and the fluorescent patterns photographed and subsequently discussed at a meeting of the Australian ANCA study group.
Results: All IIF patterns described in individual laboratories were confirmed on retesting and by the ANCA study group. Neutrophil substrates produced commercially or in house varied in their ability to demonstrate cytoplasmic granularity and interlobular accentuation, which distinguish between "C-ANCA" and "C-ANCA (atypical)". All commercial and in house neutrophil substrates demonstrated neutrophil nuclear extension of P-ANCA fluorescence, which correlates with MPO specificity. However, eight assays (eight of 43) from eight laboratories resulted in IIF patterns different from those usually seen. One of these produced a C-ANCA (atypical) rather than a C-ANCA pattern. The other seven resulted in at least some cytoplasmic fluorescence when the consensus pattern was P-ANCA with (n = 4) or without (n = 3) MPO specificity. These assays used three different commercial and one in house neutrophil substrate, and six different conjugates, with anti-IgG, anti-(Fab)`2, anti-Ig (heavy and light chain), and anti-G, A, and M activity. Four of the seven assays tested on commercial substrates had used the manufacturer's conjugates.
Conclusions: This study indicates that the variation in IIF patterns seen with ANCA positive sera tested in different laboratories does not necessarily result from errors in the interpretation of patterns and cannot be attributed solely to the use of a particular neutrophil substrate or conjugate, or to the use of substrate from one manufacturer and conjugate from another.
Keywords: antineutrophil cytoplasm antibodies; indirect immunofluorescence; vasculitis; Wegener's granulomatosis
Abbreviations: ANCA, antineutrophil cytoplasmic antibodies; C-ANCA, cytoplasmic antineutrophil cytoplasmic antibodies; ELISA, enzyme linked immunoassay; IIF, indirect immunofluorescence; MPO, myeloperoxidase; P-ANCA, perinuclear antineutrophil cytoplasmic antibodies; PR3, proteinase 3
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Trevisin, M, Neeson, P, Savige, J
(2004). The binding of proteinase 3 antineutrophil cytoplasmic antibodies (PR3-ANCA) varies in different ELISAs. J. Clin. Pathol.
57: 303-308
[Abstract] [Full Text] -
(2003). Misleading test results are not just misinterpretation. Ann Rheum Dis
62: 64-64
[Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.
